Data Sheet

Fan Model :
FD129225LL-N(1A3H)
Test Date :
2006/09/04
Key Point :
FD129225LL-N(1A3H)
Order No. :
9225L-N
Blade No. : 7 Test No. :
YS
Motor Poles : 4 Method :
Constant Voltage
Rating Voltage(V) : 12 VDC Tunnel Setup : Inlet Chamber Type
Rating Current(A) : 0.10
Temperature() : 24
R.H.(%) :
44
Rating Speed(rpm) : 1900 Barometric Pressure(mmHg) : 755.3
Test Voltage(V) : 12 VDC Acoustic ( dB(A)/1M ): 23.0dB(A)
Max. Flow rate(CFM) : 36.304 Mea. Distance(M): 1
Max. Flow rate(m
3
/min) :
1.028
Background Noise: 17.0dB(A)
Max. Pressure(in-H
2
O) :
0.059
Vibration Level (mm/sec
2
): N / A
Max. Pressure(mm-H
2
O)
:
1.501 Remark:
Voltage Current Power Speed
CFM m3/min in-H2O mm-H2O V A W rpm
1 36.304 1.0278 0.0000 0.000 12 0.097 1.159 1903
2 27.201 0.7701 0.0207 0.526 12 0.099 1.182 1817
3 18.068 0.5115 0.0291 0.739 12 0.097 1.165 1852
4 9.105 0.2578 0.0437 1.110 12 0.100 1.200 1677
5 0.000 0.0000 0.0591 1.501 12 0.100 1.200 1571
1
Yen Sun Technology Corp.
Fan Performance Test Report
Curve Pts
Flowrate Static Pressure
Fan Performance Curve
Checked: Drawn:
Approver:
江孟昌 梁益榮 張馥怡
0.0000
0.0170
0.0340
0.0510
0.0680
0.000 10.000 20.000 30.000 40.000
Static Pressure (inH2O)
Flow Rate (CFM)
YS-Q2-001-04 V1
5/7
管制文件;嚴禁複印