Data Sheet

Fan Model :
FD126025HB-N(2A7)
Test Date :
2011/02/21
Key Point :
FD126025HB-N(2A7)
Order No. :
6025-N
Blade No. : 7 Test No. :
YS
Motor Poles : 4 Method :
Constant Voltage
Rating Voltage(V) : 12 VDC Tunnel Setup : Inlet Chamber Type
Rating Current(A) : 0.18
Temperature() : 27
R.H.(%) :
78
Rating Speed(rpm) : 4200 Barometric Pressure(mmHg) : 757.8
Test Voltage(V) : 12 VDC Acoustic ( dB(A)/1M ):31.9dB(A)
Max. Flow rate(CFM) : 22.694 Mea. Distance(M): 1
Max. Flow rate(m
3
/min) :
0.642
Background Noise:17.0dB(A)
Max. Pressure(in-H
2
O) :
0.172
Vibration Level (mm/sec
2
): N / A
Max. Pressure(mm-H
2
O)
:
4.369 Remark:
Voltage Current Power Speed
CFM m3/min in-H2O mm-H2O V A W rpm
1 22.694 0.6425 0.0000 0.000 12.00 0.164 1.97 4209
2 17.011 0.4816 0.0270 0.686 12.00 0.166 1.99 4438
3 10.944 0.3098 0.0600 1.524 12.00 0.150 1.80 4608
4 6.316 0.1788 0.1190 3.023 12.00 0.162 1.95 4326
5 0.000 0.0000 0.1720 4.369 12.00 0.170 2.04 4087
Checked: Drawn:
1
Fan Performance Curve
Yen Sun Technology Corp.
Fan Performance Test Report
Curve Pts
Flowrate Static Pressure
Approver:
許志聰 許志聰 張錦華
0.0000
0.0450
0.0900
0.1350
0.1800
0.000 7.000 14.000 21.000 28.000
Flow Rate (CFM)
Static Pressure (inH2O)
FD126025HB-N(2A7)