Methods and material for containment and cleaning up
Methods for containment
Stop leak if you can do it without risk. Do not touch or walk through spilled material. A vapor
suppressing foam may be used to reduce vapors. Dike far ahead of spill to collect runoff
water. Keep out of drains, sewers, ditches and waterways. Absorb with earth, sand or other
non-combustible material and transfer to containers for later disposal.
Methods for cleaning up
Take precautionary measures against static discharges. Dam up. Soak up with inert
absorbent material. Pick up and transfer to properly labeled containers.
7. HANDLING AND STORAGE
Precautions for safe handling
Advice on safe handling
Use personal protection equipment. Avoid breathing vapors or mists. Keep away from heat,
hot surfaces, sparks, open flames and other ignition sources. No smoking. Use grounding
and bonding connection when transferring this material to prevent static discharge, fire or
explosion. Use with local exhaust ventilation. Use spark-proof tools and explosion-proof
equipment. Keep in an area equipped with sprinklers. Use according to package label
instructions. Handle in accordance with good industrial hygiene and safety practice. Avoid
contact with skin, eyes or clothing. In case of insufficient ventilation, wear suitable
respiratory equipment. Do not eat, drink or smoke when using this product. Take off
contaminated clothing and wash before reuse.
Conditions for safe storage, including any incompatibilities
Storage Conditions
Keep containers tightly closed in a dry, cool and well-ventilated place. Keep away from
heat, sparks, flame and other sources of ignition (i.e., pilot lights, electric motors and static
electricity). Keep in properly labeled containers. Do not store near combustible materials.
Keep in an area equipped with sprinklers. Store in accordance with the particular national
regulations. Store in accordance with local regulations. Store locked up. Keep out of the
reach of children. Store away from other materials.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Exposure Limits
.
Chemical name ACGIH TLV OSHA PEL NIOSH IDLH
Paraffinic, naphthenic solvent
64742-47-8
TWA: 5 mg/m
3
STEL: 10 mg/m
3
(as oil mist)
TWA: 5 mg/m
3
(as oil mist)
Titanium dioxide
13463-67-7
TWA: 10 mg/m
3
TWA: 15 mg/m
3
total dust
(vacated) TWA: 10 mg/m
3
total
dust
IDLH: 5000 mg/m
3
White mineral oil (petroleum)
8042-47-5
TWA: 5 mg/m
3
inhalable
fraction excluding metal working
fluids, highly & severely refined
TWA: 5 mg/m
3
(vacated) TWA: 5 mg/m
3
IDLH: 2500 mg/m
3
TWA: 5 mg/m
3
STEL: 10 mg/m
3
Zinc oxide
1314-13-2
STEL: 10 mg/m
3
respirable
particulate matter
TWA: 2 mg/m
3
respirable
TWA: 5 mg/m
3
fume
TWA: 15 mg/m
3
total dust
TWA: 5 mg/m
3
respirable
IDLH: 500 mg/m
3
Ceiling: 15 mg/m
3
dust
TWA: 5 mg/m
3
dust and fume