Chapter 12: Troubleshooting
Communication Wiring Issues (Satellite to Station):
For both conventional and 2-wire decoder stations, if a satellite cannot communicate
with a given station, a specific alert will be generated.
For conventional stations, verify the cable connection to the output board responsible
for that station. Verify the output board has the proper power and status LEDs
illuminated. Under the "Review -> About" menu, verify the Opt. FW for the given
output board is displayed. If the cable connection is good but the power/status
LEDs are not illuminated correctly, or the Opt. FW cannot be read, contact a Toro
service representative.
For 2-wire decoder stations, verify the cable connection to the 2-wire output board.
Verify the 2-wire output board has the proper power and status LEDs illuminated.
Verify the field wiring connection to the 2-wire output board. In the field, check the
field wiring and connections to the given station.
Diagnostics
The DXi controller utilizes several advanced tools for communication
troubleshooting. These tools are used by RMIS service personnel to diagnose and
correct field communication problems. These tools are detailed in Chapter 7:
Reports and Diagnostics.