DXi User Manual
Chapter 10: Manual Operation
Learn Now
The Learn Now command can be executed to manually learn flow and current
settings for the specified station. Learn Flow and Learn Current must be turned on
under Setup --> Stations --> Flow and Current screens.
To use the Learn Now function for current measurements, only one station can be
activated (as in, no multiple stations, master valves or pumps).
Simultaneous
The DXi controller can operate up to sixteen stations simultaneously. As you activate
stations, the DXi monitors flow and current.
To Activate Simultaneous Operation:
1) to enter Station# field.
2) to select desired station. Set it.
3) and to enter, adjust, and set Run Time.
4) Navigate to the Activate field. to begin the manual station.
Irrigation will begin immediately.
5) User must activate each station, then has the option to activate another.
Repeat steps 1-4 to activate up to fifteen more stations.
As stations are activated, the master valve (MV) and/or pump (P) associated with that
station will be highlighted, indicating they will activate along with that station. It is possible
to manually enable and disable the master valve/s and pump/s, although Toro does NOT
recommend that.
Station 001
Minimum Current 1.00
Nominal Current 1.05
Maximum Current 1.1
Learn Current
Stations
|Flow|Current|Cycle & Soak
WED 5:43:40 PM
Station 002
Minimal Flow 008
Nominal Flow 0010
Maximum Flow 0012
Learn Flow
Stations
|Flow|Current|Cycle & Soak
WED 5:43:40 PM
Station# 002 MV: 1 2 3
Run Time 060 P: 1 2
Activate Deactivate
Status: Off
Flow: 24 (GPM) Cur:0.01
Running:
Manual Simultaneous WED 5:43:40 PM