Appendix D: Setting Up a FLOW MAX System
Flow Max Setup Procedure
The following section details the programming required in order to setup a Flow Max
configuration. Programming must be performed at all controllers that will be part of
the Flow Max system.
A typical Flow Max setup includes the following:
Submaster:
Submaster Address Entry
Participant Selection / Devices Connected to this Clock
Include in Total Flow
Flow Meter K and Offset Values (if connected to this satellite)
Station Number and Valve/Pump Assignments
Unscheduled Flow Limits
Main Line Limit
Monthly Limit
Flow Limit Checking
Satellite (Non-Participant):
Non-participant selection
Satellite (Participant):
Participant selection /Devices Connected to this Clock
Include in Total Flow
Flow Meter K and Offset Values (if connected to this satellite)
This procedure utilizes the configuration depicted in Figure D-1: Hardwire
Configuration with a submaster address of 1-0. The figure illustrates a system
consisting of three controllers, a Pump, one Master Valve and one 2-inch Flow
Sensor. The Pump is physically connected to the submaster. The Master Valve and
Flow Sensor are physically connected to satellite with the address 1-1. Table 1: Flow
Max Sample Worksheet lists the parameters for each controller.