Manual

125
DXi User Manual
Appendix D: Setting Up a FLOW MAX System
Submaster
Controller
Address 1–0
Satellite
Address 1–1
Satellite
Address 1–2
Flow
Sensor
Master
Valve
Pump
Zone
Valve
Zone
Valve
Zone
Valve
Zone
Valve
EV-CAB-COM EV-CAB-COM
EV-CAB-SEN
Zone
Valve
Zone
Valve
Figure D-1: Flow Max Hardwire Conguration
EV-CAB-COM
EV-CAB-COM
EV-CAB-COM
EV-CAB-COM
SATELLITE
ADDRESS 1-1
SUBMASTER CONTROLLER
ADDRESS 1-0
SATELLITE
ADDRESS 1-2
DX-HW, DX-PH OR DX-RF
COMMUNICATION BOARD
DXi COMM BOARD
+IN- +OUT- GND
+ -
+ -
DX-HW, DX-PH OR DX-RF
COMMUNICATION BOARD
DXi COMM BOARD
+IN- +OUT- GND
+ -
+ -
DX-HW, DX-PH OR DX-RF
COMMUNICATION BOARD
DXi COMM BOARD
+IN- +OUT- GND
+ -
+ -
Copper
Wire
From “OUT” port
of DX-XX
From “OUT” port
of DX-XX
From “OUT”
port of DX-XX
SUBMASTER
CONTROLLER
ADDRESS 1-0
SATELLITE
ADDRESS 1-1
SATELLITE
ADDRESS 1-2
From “OUT”
port of DX-XX
To “IN” port
of DX-HW
To “IN” port
of DX-HW
To “IN” port
of DX-HW
Tinned
Wire
Copper
Wire
Tinned
Wire
Tinned
Wire
Copper
Wire
To “IN” port
of DX-HW
Figure D-2: Detailed Hardwire Connections