Appendix C: Current Alarms Within a Conventionlly Wired DXi System
Scenario 8 - DXi submaster 001-00 begins an automatic irrigation operation of
program 9 by activating MV1, Pump1 then station 1. Next DX2 satellite 001-02 begins
an automatic irrigation operation of program 5 by activating station 4. After station 4 is
activated by DX2 satellite 001-02 the measured current is below the minimum allowed
current.
FLOW
MAX
Group
Satellite
Type
Master
Valves
"ON"
Pumps
"ON"
Station
"ON"
Min
Current
Nominal
Current
Max
Current
Total
Min.
Current
Total
Measured
Current
Total
Max.
Current
Sub
001-00
DXi M1 P1 1 M1 = 0.20
P1 = 0.25
S1 = 0.15
M1 = 0.25
P1 = 0.30
S1 = 0.20
M1 = 0.29
P1 = 0.34
S1 = 0.24
0.6 0.75 0.87
Sat
001-01
DXi
Sat
001-02
DX2 4 S3 = 0.10 S3 = 0.15 S3 = 0.20 0.1 .09 0.2
Sat
001-03
DX2
Result 8 - DX2 satellite 001-02 deactivates S4, raises alarm 1005 "I Low Limit", and
condemns S4.
DX2 satellite 001-02 resumes automatic irrigation operation of program 5, for none
condemned stations. Manual or automatic operations will not activate S4 until alarm is
cleared
Note, Irrigation at submaster 001-00 is not affected in this scenario.
Scenario 9 - DXi submaster 001-00 begins an automatic irrigation operation of
program 8 by activating station 1. Next DX2 satellite 001-02 begins an automatic
irrigation operation of program 6 by activating MV1, Pump1 then station 4. After
station 4 is activated by DX2 satellite 001-02 the measured current is above the
maximum allowed current.
FLOW
MAX
Group
Satellite
Type
Master
Valves
"ON"
Pumps
"ON"
Station
"ON"
Min
Current
Nominal
Current
Max
Current
Total
Min.
Current
Total
Measured
Current
Total
Max.
Current
Sub
001-00
DXi 1 S1 = 0.15 S1 = 0.20 S1 = 0.24 0.15 0.2 0.24
Sat
001-01
DXi
Sat
001-02
DX2 M1 P1 4 M1 = 0.20
P1 = 0.25
S1 = 0.15
M1 = 0.25
P1 = 0.30
S1 = 0.20
M1 = 0.29
P1 = 0.34
S1 = 0.24
0.6 1
0.87
Sat
001-03
DX2
Result 9 - DX2 satellite 001-02 deactivates S4, raises alarm 1004 "I High Limit", and
condemns S4.
DX2 satellite 001-02 resumes automatic irrigation operation of program 6, for none
condemned stations. Manual or automatic operations will not activate S4 until alarm is
cleared
Note, Irrigation at submaster 001-00 is not affected in this scenario.
Note, DX2 controllers can't run diagnostic or condemn Master Valves or Pumps.