Manual

105
DXi User Manual
Appendix A: Specifications
Appendix B: Flow Sensors
The DXi controller provides a variety of user-configurable, flow-related features
for up to three flow sensors, referred to as Flow #1, Flow #2, and Flow #3. Flow
sensors may be of both conventional and/or decoder type.
DXi flow features/capabilities include:
Display of instantaneous flow rate in gallons per minute (GPM) for all three
meters as well as total (Flow #1 + Flow #2 + Flow #3). Flow rates are updated
every ten seconds.
Display of monthly flow accumulations in gallons for all three flow meters as well
as total (Flow #1 + Flow #2 + Flow #3). Flow accumulation in gallons is updated
every minute.
Automatic termination of watering based upon flow limit violations:
Main line flow rate for controller (GPM)
Maximum flow rate per station (GPM)
Minimum flow rate per station (GPM)
Maximum flow accumulation per month (gallons)
Unscheduled flow rate for controller (GPM)
Automatic condemnation and reporting of stations violating flow limits.
Alert information is provided in Chapter 8: Alerts.
Automatic establishment of station upper and lower flow limits (Learn mode).