Product Literature
3 | P a g e P a r t N o . 5 0 0 6 7 6 R e v . A
4. 0 - Maintenance and Alarm Diagnostic Capabilities
4.1 Flow monitoring. Automatic alarm processing (which provides station and/or master
valve shut down and program advance as required) diagnosing and reporting station
underflow and overflow, mainline breaks, and unscheduled flows.
4.2 Electrical field wire monitoring. Automatic alarm processing (which provides station
shutdown and program advance/pause) for station over current, short circuits, broken
field wiring or faulty solenoids.
4.3 Power monitoring. Automatic alarm processing/reporting for power outages and power
restoration. Intelligent program resumption for all outages or power glitches, no lost
cycles or water window violations.
4.4 Diagnostic lights (LEDs) for system power and all station outputs as well as the dedicated
outputs. Lights indicate when 24 VAC is at output terminal.
4.5 Built-in test (BIT) functions allow selected controller circuitry to be field-tested.
4.6 Manual test mode. Allows user to automatically advance from station to station using
manual run time while displaying valve solenoid electrical current for each station as well
as station flow in gallons per minute (GPM).
4.7 Manual station and manual multi-station modes. Turns on any station for user entered
runtime and automatically selects usage of the proper master valve and/or pump for this
station. Multi-station mode allows any single station or output to be turned on
individually or in combination with any other station(s). Valve solenoid electrical current
is displayed.
4.8 Manually entered program. Allows user to enter a one-time program to be run
immediately or scheduled for later in the day. The manual program is independent of
automatic programs and shall start only one time.
4.9 Manual start of automatic programs (1-16). Start any program independent of the
scheduled start time and water day.
4.10 Interior lighting (fridge light) for service & maintenance.
4.11 Pivoting brackets (Pivotech
™
) for ease of field wiring connections.
5.0 - Miscellaneous Features
5.1 Central control capable with WMS Software.
5.2 Operates as a standalone.
5.3 Automatic limit setup (learn mode) for flow. Percentage adjust for limit establishment.
5.4 ProMax Connect™ smartphone application compatible for cellular, Ethernet and WiFi