Chapter 12: Troubleshooting
Display is blank
Start
At
MV board,
are all 5 power LEDs
illuminated?
Is the fuse blown?
Yes No
Yes
No
Consult Rain Master
technical support.
Replace fuse
and retest.
Verify AC power switch
inside controller is in
the “On” position.
Verify GFI circuit breaker
is reset. Press “red” button
to reset.
Verify main circuit breaker
at remote power source
is on.