DXi User Manual
Chapter 8: Alerts
Power ON
This alert is triggered when the controller resets and restarts after a power disruption.
Daily / Hourly Rain Limit
This alert is triggered when rain exceeded daily / hourly rain limit.
Wind Exit / Enter Contition
This alert is triggered when wind was below / above limit for prescribed time, wind
shutdown is ended / started.
Upload Request
User has indicated they wish controller settings to be uploaded by the central.
Clear All Alerts
Clearing this alert will clear all alerts, and all underlying flags that may have been
orphaned if alerts were overwritten.
Station Open Circuit
This alert is triggered when decoder reports open circuit.
Station Over Current
This alert is triggered when decoder reports over current after initial power up.
Over current is defined 1Amp or higher.
Decoder Ports Exceeded
This alert is triggered when decoder reports too many ports on.
Decoder No AC Voltage
This alert is triggered when decoder reports no AC voltage.
MV Current Upper Limit
Indicates Master Valve current draw exceeded the maximum allowed. Alert will
display the measured current and maximum limit.
MV Current Lower Limit
Indicates Master Valve current draw was below the minimum allowed. Alert will
display the measured current and minimum limit.
Pump Current Upper Limit
Indicates Pump current draw exceeded the maximum allowed. Alert will display the
measured current and maximum limit.
Pump Current Lower Limit
Indicates Pump current draw was below the minimum allowed. Alert will display the
measured current and minimum limit.
FLOW MAX Lower Limit (Submaster Only)
Indicates actual flow was below minimum flow allowed. Alert will display measured
flow and lower limit.
FLOW MAX Upper Limit (Submaster Only)
Indicates actual flow was above maximum flow allowed. Alert will display measured
flow and upper limit.