DXi User Manual
Chapter 8: Alerts
Hardware (HW) Communication Failure
Set on submaster to indicate it lost communication with a satellite not configured for
Flow Max.
Flow Max (FM) Communication Failure
Set on submaster to indicate it lost communication with a satellite configured for
Flow Max.
Flow Max Stop Water
This alert is triggered when the controller is in a stop watering state.
Flow Max Multiple Flow Meters
This alert is triggered when the specified flow meter is defined on more than one
controller in the Flow Max group. DXi will add flows together for multiply defined
flow meters.
Flow Max Multiple Pumps
This alert is triggered when more than one controller in the flow max group has the
specified pump defined. DXi will operate all multiply defined pumps in tandem.
Flow Max Multiple Master Valves
This alert is triggered when more than one controller in the flow max group has the
specified master defined. DXi will operate all multiply defined masters in tandem.
Current Upper / Lower Limit
This alert is triggered when actual current was above maximum current or below the
minimum current allowed.
Main Flow Limit
This alert is triggered when flow exceeded main line flow limit.
Unscheduled Flow Limit
This alert is triggered when flow exceeded unscheduled flow limit.
Station Short Circuit
This alert is triggered when decoder reports short circuit on initial power up.
Short circuit is defined as 1Amp or higher.
Auto Limits Aborted
This alert is triggered when auto limits process was terminated before completion.
Flow Max Communication Restored
Flow Max configured satellite triggers this alert when it has established or restored
communication with the Submaster.
Flow Max Station Advance
This alert is triggered when the satellite is a FLOWMAX participant and received
station advance from a FLOWMAX related alarm.