Manual

55
DXi User Manual
Chapter 8: Alerts
Chapter 8: Alerts
The DXi series controller automatically alerts the operator when problems occur or
certain conditions arise. The controller may trigger an alert in response to over 11
different conditions. Each condition is date/time stamped and includes additional
information which may be helpful in troubleshooting the problem. Up to 100 alerts
may be saved in the controller at one time. The user may delete alerts at any time.
Some alerts, such as a main line limit violation, require immediate attention as all
irrigation activity is condemned until the alarm is cleared.
Most alerts, due to the controller's programming, do not necessitate immediate
operator attention. For example, consider a station with a broken head (FLOW
UPPER LIMIT warning). Upon detection of this failure, the DXi controller will:
1. Turn the failed station off.
2. Mark the station as condemned (will not water again until
the alarm/warning is cleared).
3. Advance to the next scheduled station in the program.
4. Report the failed station as a warning.
Alert #:001 of 004
Type: Controller reset
Recorded: 05/25/21 17:41
P/MV: ---
Stn: ---
Limit: 1:03 m:s off
Press ‘A’ to clear alert ‘B’ to clear all
Alerts WED 5:43:40 PM