Manual
46
DXi User Manual
Chapter 6: Station Options
Type
When you turn on a station, the station may be one of several different types. When
setting up the station Type, it is necessary to fill in all the requested parameters for the
controller to communicate with the station correctly.
The DXi controller will most commonly use Local, Wireless-LR and AC decoder
types, but we include others for legacy reasons.
Local
For a Local output on the controllers directly connected output boards, no additional
parameters are needed. When you operate station 5 set to local the terminal output 5
on the first output board will be activated just as any basic controller.
Wireless-LR
When you choose Wireless-LR, commands are sent to the Wireless-LR designated
port and radio. To properly address a Wireless-LR board you must complete:
• Precode: Set to the precode the WOB bord is trained to (000-999) Typically this
is set to the same as the unit code of the controller.
• Board # (0-30) – This corresponds to the position of the rotary switch on the
WOB board.
Note: Switch positions labelled A = 10, B=11, C=12, D=13, E=14, and F = 15
• Output # (1-48) This corresponds to the output terminal desired on the WOB
board.
Station 001
Type Local
Stations
|Flow|Misc|Cycle & Soak|Type
WED 5:43:40 PM
Station 001
Type Wireless LR
Precode
Board # (0-30) 000
Output # (1-48) 000
Socket # (1-4) 000
Stations
|Flow|Misc|Cycle & Soak|Type
WED 5:43:40 PM