Manual

41
DXi User Manual
Chapter 5: Program Entry
Cycle Delay (sec): This is the amount of time, in seconds, that the Master Valve and
Pump will wait after a Program's start time before operating. The reason for this is to
make sure irrigation channels are open before water starts being pumped and flowing.
A pump can be damaged if it begins pumping with no outlet for the water.
Volumetric Shutdown: Yes or No. If the controller enters the Volumetric Shutdown
state (by using more than the allotted amount of water over the allotted interval),
programs set to Yes will not be allowed to irrigate. Programs set to No will run
regardless of the Volumetric Shutdowns state. Programs set to Yes will allow starts to
run after the Volumetric shutdown is cleared.
Moisture Control: Yes or No. Moisture Control enables data logging and collection
of moisture data. For complete installation and setup instructions for a moisture
sensor, please see Toro document 373-1021, TW-DAC-SOIL Moisture Sensor
Installation Guide.
Erase/Reset
To Erase a Program
1. to Program Menu Page 2.
2. to YES/NO field. to enter.
3. to change to YES. to set.
4. to Apply Changes field. to set.
Repeats
Setting the % Adjust
Program 1 Erase NO
Apply Changes
Program 1 Erase WED 5:43:40 PM