Manual

29
DXi User Manual
Chapter 4: Setup
Press or to get to the next group of Omit Days.
Communication
General
The controller can communicate with the Central running Sentinel WMS in any one
of five methods:
4G LTE
UHF radio
Wifi
3G
Other
If a device is detected, the controller will set this option.
The Unit Code can be any number between 001 and 999. If you were to have more
than one DXi controller attached to any one Central computer, be sure they have
different Unit Code addresses.
Group Code is any number from 001 to 999. When set, the Sentinel Water
Management Software (WMS) can send communication commands simultaneously to
a group of satellites with the same Group Code number. Note that each satellite will
not respond to this transmission but will act on the transmission if the command is a
"group eligible" command such as a Rain Shutdown.
Use the Control Dial to activate, select a communication method, and assign an
address for these fields.
Press or to get to “Ethernet” screen.
Off
Ethernet
Wi-Fi
Cellular
Unit Code: 001
Comm Option Device:
WiFi
Group Code: 240
Cloud Connect: Ethernet
Setup Communication WED 5:43:40 PM
|General|ENET|WiFi|UHF|Cell
4G LTE
UHF radio
WiFi
Other
3G
None