Appendix C: Hardwired Communication Troubleshooting
Appendix C:
Hardwired Communication
Troubleshooting
Toro® DXi controllers are capable of communication between controllers to allow
sharing of flow devices, Master Valves, pumps, as well as communication to Sentinel
WMS central software. Controllers share communication via a hardwired connection.
The hardwired communication is made via the EV-CAB-COMM cable due to its
specific direct burial and communication properties. Each controller is wired in a
daisy-chain configuration with the submaster being the starting point and the last
controller being the ending point. Controller-to-controller connections are made via
the "DXi COMM BOARD" as seen below in figure D-2.
EV-CAB-COM
EV-CAB-COM
EV-CAB-COM
EV-CAB-COM
SATELLITE
ADDRESS 1-1
CONTROLLER
ADDRESS 1-0
SATELLITE
ADDRESS 1-2
DX-HW, DX-PH OR DX-RF
COMMUNICATION BOARD
DXi COMM BOARD
+IN- +OUT- GND
+ -
+ -
DX-HW, DX-PH OR DX-RF
COMMUNICATION BOARD
DXi COMM BOARD
+IN- +OUT- GND
+ -
+ -
DX-HW, DX-PH OR DX-RF
COMMUNICATION BOARD
DXi COMM BOARD
+IN- +OUT- GND
+ -
+ -
Copper
Wire
From “OUT” port
of DX-XX
From “OUT” port
of DX-XX
From “OUT”
port of DX-XX
CONTROLLER
ADDRESS 1-0
SATELLITE
ADDRESS 1-1
SATELLITE
ADDRESS 1-2
From “OUT”
port of DX-XX
To “IN” port
of DX-HW
To “IN” port
of DX-HW
To “IN” port
of DX-HW
Tinned
Wire
Copper
Wire
Tinned
Wire
Tinned
Wire
Copper
Wire
To “IN” port
of DX-HW