Data Sheet
VNH5019A-E Revision history
Doc ID 15701 Rev 9 35/37
6 Revision history
Table 21. Document revision history
Date Revision Changes
22-Jan-2008 1 Initial release.
04-Nov-2009 2
Uploaded corporate template by using V3 version
Added Table 5: Thermal data
Section 2.1: Absolute maximum ratings
– Added text
Table 6: Power section
–I
S
: added max value for IN
A
= IN
B
= PWM = 0; T
j
= 25 °C;
V
CC
=13V in Test conditions, deleted IN
A
= IN
B
= PWM = 0
–V
f
: changed Test conditions, changed typ/max value
–I
RM
: deleted and copied in Table 8: Switching (V
CC
= 13 V,
R
LOAD
= 0.87 W, Tj = 25 °C) whole row
Table 8: Switching (V
CC
= 13 V, R
LOAD
= 0.87 W, Tj = 25 °C)
–t
DEL
: changed min/typ/max value
–Copied I
RM
row by Table 6: Power section
Updated Table 10: Current sense (8 V < V
CC
< 21 V)
Table 11: Charge pump
–V
CP
: changed min/max value for EN
X
= 5 V, changed typ
value for EN
X
= 5 V, V
CC
= 4.5 V
Updated Figure 11: Waveforms in full bridge operation (part 1)
Updated Figure 12: Waveforms in full bridge operation (part 2)
Added Chapter 4
16-Dec-2009 3
Updated following tables:
– Table 6: Power section
– Table 9: Protection and diagnostic
– Table 10: Current sense (8 V < V
CC
< 21 V)
Added Figure 6: Behavior in fault condition (how a fault can be
cleared)
Added Chapter 3: Package and PCB thermal data
06-Apr-2010 4
Updated Table 5: Thermal data.
Table 6: Power section:
–I
S
: updated test condition and max value
Updated table notes on Table 9: Protection and diagnostic.
Table 10: Current sense (8 V < V
CC
< 21 V):
–dK
0
/k
0
, dK
1
/k
1
, dK
3
/k
3
: updated minimum end maximum
values.
19-Apr-2010 5 Updated Table 10: Current sense (8 V < V
CC
< 21 V).
25-May-2010 6
Updated Features list.
Updated Table 6: Power section.
02-Sep-2010 7 Updated Table 5: Thermal data.