Data Sheet

VNH5019A-E Package and PCB thermal data
Doc ID 15701 Rev 9 29/37
Figure 22. Thermal fitting model of an H-bridge in MultiPowerSO-30
Table 18. Thermal parameters
(1)
1. The blank space means that the value is the same as the previous one.
Area/island (cm
2
) Footprint 4 8 16
R1 = R7 (°C/W) 0.1
R2 = R8 (°C/W) 0.3
R3 = R10 = R16 (°C/W) 0.5
R4 (°C/W) 6
R5 (°C/W) 30 24 24 24
R6 (°C/W) 56 52 42 32
R9 = R15 (°C/W) 0.05
R11 = R17 (°C/W) 0.7
R12 = R18 (°C/W) 10
R13 = R19 (°C/W) 36 26 26 26
R14 = R20 (°C/W) 56 42 36 28
R21 = R22 (°C/W) 35 25 25 25
R23 (°C/W) 160 150 150 150
C1 = C7 = C9 = C15 (W.s/°C) 0.005
C2 = C8 (W.s/°C) 0.01
C3 (W.s/°C) 0.03
C4 (W.s/°C) 0.4
C5 (W.s/°C) 1.5 2 2 2
C6 (W.s/°C) 3 4 5 6
C10 = C16 (W.s/°C) 0.015
C11 = C17 (W.s/°C) 0.05
C12 = C18 (W.s/°C) 0.3
C13 = C19 (W.s/°C) 1.2 2 2 2
C14 = C20 (W.s/°C) 2.5 3 4 5
C21 = C22 = C23 (W.s/°C) 0.01 0.008 0.008 0.008