SDS

Nisus DSV Specimen Label • SAL102110 • page Page 8 of 18
hard, inanimate, non-porous surfaces, thoroughly wet-
ting surfaces with a brush, cloth, mop, sponge or me-
chanical spray device. For sprayer applications, use a
coarse spray device. Spray 6-8 inches from surface. Rub
with brush, sponge, mop or cloth. Do not breathe spray.
Treated surfaces must remain wet for 10 minutes. Rinse
or allow to air dry. Prepare a fresh solution at least daily
or when use solution becomes visibly dirty.
Note: With spray applications cover or remove all food
products.
*VIRUCIDAL PERFORMANCE: For heavily soiled are-
as, a preliminary cleaning is required. Apply 2 ounces
per gallon of water use level (or equivalent use dilution)
to treated surfaces, thoroughly wetting surfaces with a
brush, cloth, mop, sponge or mechanical spray device.
For sprayer applications, use a coarse spray device.
Spray 6-8 inches from surface. Rub with brush, sponge,
mop or cloth. Do not breathe spray. Treated surfaces
must remain wet for ten minutes. Prepare a fresh solu-
tion at least daily or more often if solution becomes
soiled.
At 1 1/4 ounce per gallon of water (or equivalent use
dilution) in the presence of 5% blood serum and 400
ppm of hardness for a 2-minute contact time, this prod-
uct was found to be effective against HIV-1 (AIDS Virus).
At 2 ounces per gallon of water (or equivalent use
dilution) and in the presence of 400 ppm hard water
(CaCO
3
) and 100% serum, this product was proven to
be effective against (Duck) Hepatitis B Virus with a
contact time of 10 minutes.
At 2 ounces per gallon of water (or equivalent use
dilution) and in the presence of 400 ppm hard water
(CaCO
3
) and 5% organic load, this product was proven
to be effective against Bovine viral diarrhea virus
(BVDV), a surrogate for human Hepatitis C virus with a
contact time of 10 minutes.
*KILLS HBV, HCV and HIV ON PRECLEANED ENVI-
RONMENTAL SURFACES/OBJECTS PREVIOUSLY
SOILED WITH BLOOD/BODY FLUIDS in health care
setting or other settings in which there is an expected
likelihood of soiling of inanimate surfaces/objects with
blood or body fluids and in which the surfaces/objects
likely to be soiled with blood or body fluids can be asso-
ciated with the potential for transmission of (Duck) Hepa-
titis B Virus (HBV), human immunodeficiency virus Type
1 (HIV-1) which is associated with AIDS, and Hepatitis C
Virus (HCV).
“SPECIAL INSTRUCTIONS FOR CLEANING AND
DECONTAMINATION AGAINST HBV, HCV AND HIV-1
ON SURFACES/OBJECTS SOILED WITH BLOOD/
BODY FLUIDS.”
Personal Protection: Specific barrier protection items to
be used when handling items soiled with blood or body
fluids are disposable latex gloves, gowns, masks, and
eye protection.
Cleaning Procedure: Blood and other body fluids con-
taining HIV-1, HBV & HCV must be thoroughly cleaned
from surfaces and objects before application of this
product.
Disposal of Infectious Materials: Blood and other body
fluids, cleaning materials and clothing must be auto-
claved and disposed of according to federal, state and
local regulations for infectious waste disposal.
Contact Time: Leave surface wet for 2 minutes and 10
minutes for HIV-1 and HBV, respectively. This 2-minute
contact time will not control other common type of virus-
es and bacteria listed on this label. For HCV, leave sur-
face wet for 10 minutes.
SURGICAL INSTRUMENT PRESOAK: Add 2 ounces of
this product to 1 gallon of water (or equivalent use dilu-
tion). Place pre-cleaned instruments in solution to pre-
soak surgical instruments for a minimum of 10 minutes,
then proceed with normal sterilization procedure. Pre-
pare a fresh solution at least daily or more often if solu-
tion becomes visibly dirty.
Note: Plastic instruments can remain immersed until
sterilization. Metal instruments must be removed after 10
minutes, rinsed, dried, and kept in a clean non-
contaminated receptacle until sterilization. Prolonged
soaking will cause damage to metal instruments. Surgi-
cal instruments must be sterilized before use.
ULTRASONIC BATH DISINFECTANT/FUNGICIDE DI-
RECTIONS: Use this product to disinfect hard, non-
porous, non-critical objects compatible with Ultrasonic
cleaning units. Pour a fresh solution of 2 ounces of this
product per gallon of water (or equivalent use dilution)
directly into bath chamber. Pre-clean heavily soiled ob-
jects. Place objects into unit and operate for a minimum
of 10 minutes, according to the manufacturers’ use di-
rections. Remove objects and wash with sterile water or
allow to air dry. Prepare fresh solution for each use.
FOR DISINFECTING / FUNGICIDAL ON HARD, NON-
POROUS FIBERGLASS BATH AND THERAPY
EQUIPMENT: To remove body oils, dead tissue, soil
and all other buildups or organic matter on inanimate
surfaces after using the unit, drain the water and refill
with fresh water to just cover the intake valve. Add 2
ounces of this product for each gallon of water (or equiv-
alent use dilution) in the unit at this point. Briefly start the
pump to circulate the solution. Turn off pump. Wash
down the unit sides, seat of the chair lift, and any/all re-
lated equipment with a clean swab, brush or sponge.
Product to surface contact time must be at least 10
minutes for proper disinfection. After the unit has been
thoroughly disinfected, drain solution from the unit and
rinse any/all cleaned/disinfected surfaces with fresh wa-
ter. The unit is ready for reuse.
CLEANING AND DISINFECTING HARD, NON-
POROUS SURFACES ON PERSONAL PROTECTIVE
EQUIPMENT (RESPIRATORS): Pre-clean equipment if
heavily soiled to ensure proper surface contact. Apply a
2-ounce per gallon of water (or equivalent use dilution)