Manual

NOTES:
Landscape Dripline Design _____________________________________________________________
Installation Procedures
Installation Steps
Assemble and install lter, remote control valve and pressure-
regulating valve assembly(ies) according to detail numbers
1 and 2, p. 23.
Assemble and install supply header(s) according to detail numbers
3, 5, 4 and 6, p. 24-25. Tape or plug all open connections to
prevent debris contamination.
Assemble and install exhaust header(s) in accordance with detail
numbers 7 and 8, p. 26. Tape or plug all open connections to
prevent debris contamination.
Install dripline laterals. Tape or plug all open ends while installing
the dripline to prevent debris contamination.
Install air vacuum relief valve(s) at the highest point(s) of the
zone(s) according to detail numbers 9, 10, 11 and 12, p. 27-28.
(only required on subsurface installations)
Thoroughly ush supply header(s) and connect dripline laterals
while ushing.
Thoroughly ush dripline laterals and connect to exhaust header(s)
or interconnecting laterals while ushing.
Thoroughly ush exhaust header(s) and install line ushing valves
according to detail number 13, p. 29.
Thorough ushing of each installation segment is
necessary to ensure that no debris contamination
occurs.
22