Instructions / Assembly

3. Test furnace for proper ignition and operation.
4. Verify that the Power-On LED, on the power module, is on during the Glo-Stix™ igniter
warmup.
5. During igniter warm-up, using a true RMS voltmeter, measure the voltage across the igniter.
Voltage should be between 50 VAC and 120
VAC.
6. Make sure the Glo-Stix™ igniter does not remain energized in the flame for more than a few
seconds.
7. Replace the burner compartment door.
8. Place Glo-Stix™ upgrade label on front of the appliance, write the date of installation and your
contact details.
We strongly recommend that the installation is carried out by a qualified gas appliance engineer.
Take care to follow the recommended fitting instructions carefully. Failure to do so will void the
warranty and maylead to personal injury or damage to property.
Fire Hazard
Under no circumstances exceed the specified voltage of 120 volts. Ensure that components do not
come into direct contact with water (for example, spray, dripping water or rain). Improper and
dangerous operation can result from wiring errors. Ensure that wiring is routed securely, and
away from any flame.
Shock Hazard Always turn off electric power before
working on any
appliance. Ensure proper
connection of line hot
wires.
Explosion Hazard Shut off main gas to appliance before installation begins, and do not
reconnect until installation is co