Instructions / Assembly

The Inside Story on Automatic Gas Safety
The Safety+PLUS valve’s patented magnet-
based technology offers distinct advantages
over spring-actuated devices.
How it Works
A gas line rupture produces an unrestricted gas ow
through the valve, forcing the plate away from the
magnet. The plate seals rmly against the seat,
immediately restricting gas ow to avert a
hazardous release of gas into the home.
In standard operating conditions, the magnet
holds the metal plate in place, allowing gas to
ow to the appliance.
Metal Plate
Magnet
Internal Seat
Metal Plate
Magnet
Internal Seat Bypass Flow
Activation of the
Safety+PLUS valve
restricts gas ow to
less than 5 SCFH; the
bypass ow. This
non-hazardous bypass
is used to re-pressurize
the repaired gas line,
and automatically reset
the valve, resuming
normal gas ow to
the appliance.
Internal Seat
Magnet
Metal Plate
Standard – OPEN Gas Rupture – ACTIVATED Automatic Reset
• Employsnopartsthatcanwear,breakormisalignovertime.
• Magnetssuffernomemorylossduetometalfatigue.
• Valveactivationisnotgravitydependent,soitcanbeinstalledineither
a horizontal or vertical position.