Specification

HIGH PERFORMANCE CEILING FANS
MODEL: CP48HPWP
Features
Performance Data & Specifications
Ratings
CEILING FAN SPEED CONTROLS
MODELS: “MC” CONTROL & “FRMC5” CONTROL
“MC” CONTROL
24.375”
7.6”26”
Engineered and designed for spacious applications where maximum floor coverage is required.
Reversible motor for both winter destratification and summer time cooling
Fans are sealed and suitable for high moisture applications.
All high performance fans are weather resistant.
Straight blades and heavy duty motors for higher air movement and better cooling capacity.
Model Number Fan Size Max RPM
Air Velocity 5'
from fan
Air Delivery
@ floor
Amps High Watts High
Downrod
Length
Shipping
Weight (Lbs.)
CP48 HPWP 48" 325 700 ft/min 21,000 cfm 0.63 62 16" 18.00
Model Number Max # of Fans/control Variable Speed Operation Power Supply Ampere Rating
MC-3 2 2.5
MC-5 4 5.0
MC-10 8 10.0
MC-15 12 15.0
FRMC5 4 Manual c/w Forward/Reverse Switch 5.0
120V/1/60HZ
Manual
CANARM LTD. - Corporate Office
2157 Parkedale Ave., PO Box 367
Brockville, ON Canada K6V 5V6
Tel: (613) 342-5424 Fax: 1-800-263-4598
CANARM LTD. - USA Warehouse
808 Commerce Park Drive
Ogdensburg, New York, USA 13669
Tel: 1-800-267-4427 Fax: 1-800-263-4598
www.canarm.com E-Mail: hvacsales@canarm.ca
Arthur Manufacturing Facility
#7686 Concession 16, RR 4 Arthur, ON
Canada N0G 1A0
Tel: (519) 848-3910 Fax: (519) 848-3948
HEAVY DUTY • HIGH PERFORMANCE • MAXIMUM OUTPUT
NOV/2012
Subject to change without notice. 05/12
Available in 4 models: 3 amp, 5 amp, 10 amp and 15 amp.
• The MC15 can operate up to 12 fans on a single control.
Infinite speed adjustment
Minimum speed adjustment screw.
Designed to fit a standard 3” x 5” electrical box.
Mount in a dry location such as the control room.
A slide switch is provided to change the direction
of the fan from updraft to downdraft.
5 amp rating for all reversible models.
Up to 4 fans can operate on a single control.
Infinite speed adjustment.
Minimum speed adjustment screw.
Designed to fit a standard 3” x 5” electrical box.
Mount in a dry location such as the control room.
OFF
HIGH
LOW
OFF
HIGH LOW
“FRMC5” CONTROL
23”
24 3/4”
7 5/8”
19 3/4”

Summary of content (1 pages)