Datasheet
5 Other items:
5.1 Disconnect the temperature detection heating rate should be controlled for 1 ° c / 1min, Use process cannot
bear strong impact and stress.
5.2 Models of specifications BK05——
production specifications XXX℃——
voted disconnect temperature
6 This standard should separately conclude when not related to other matters or customer requirements.
opening and reset temperature drawing
NO.
Disconnect
Reset temp.
NO.
Disconnect
Reset temp.
temp.
temp.
30
30 ± 3℃
≥20
℃
95
95 ± 5℃
70 ± 15℃
35
35 ±3.5℃
≥25
℃
100
100 ± 5℃
70 ± 15℃
40
40 ± 4℃
≥30
℃
105
105 ± 5℃
75 ± 15℃
45
45 ± 4.5℃
≥33
℃
110
110 ± 5℃
75 ± 15℃
50
50 ± 5℃
≥35
℃
115
115 ± 5℃
80 ± 15℃
55
55 ± 5℃
42 ± 6℃
120
120 ± 5℃
85 ± 15℃
60
60 ± 5℃
45 ± 8℃
125
125 ± 5℃
85 ± 15℃
65
65 ± 5℃
48 ± 10℃
130
130 ± 5℃
90 ± 15℃
70
70 ± 5℃
50 ± 12℃
135
135 ± 5℃
95 ± 15℃
75
75 ± 5℃
53 ± 14℃
140
140 ± 5℃
100 ± 15℃
80
80 ± 5℃
55 ± 15℃
145
145 ± 5℃
100 ± 15℃
85
85 ± 5℃
60 ± 15℃
150
150 ± 5℃
105 ± 15℃
90
90 ± 5℃
65 ± 15℃
155
155 ± 5℃
110 ± 15℃
Distributed by Conrad Electronic SE
This data sheet is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights including translation reserved. Reproduction by any
method, e.g. photocopy, microfilming, or the capture in electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This data
represent the technical status at the time of printing. Changes in technology and equipment reserved.
© Copyright 2016 by Conrad Electronic SE.