21
b. Lubricating points
Lubricate the marked points according to the maintenance checklist. The required grease specification is:
DIN 51825, standard grease.
c. Check and refill hydraulic oil
It is recommended to use hydraulic oil in connection with average temperature:
Environment temperature
23~77
–5~25℃)
>77
>25℃)
Type
HVLP 32
DIN 51524
HLP 46
DIN 51524
Viscosity
28.8-35.2
41.4 - 47
Amount
0.4L
Waste material like oil, used batteries or other must be probably disposed and recycled according to the
national regulations and if necessary brought to a recycling company.
The oil level height shall be in the not lifted position min. 0.3L to 0.5L.
If necessary add oil at the filling point.
1. Load roller bearing
2. Cylinder
3. Axle
4. Bearing
5. Gear box
6. Side roller bearing
7. Connection point
Fig. 13: Lubricating points