Product Manual

14
f. Braking
PLEASE CHECK THE BRAKING DISTANCE WITH TRUCK BEFORE OPERATION
THE BRAKING PERFORMANCE DEPENDS ON THE TRACK CONDITIONS AND
THE LOAD CONDITIONS OF THE TRUCK
The braking function can be activated on several ways:
By moving the accelerator button (13) back to the initial ‘0’ position or by releasing the button, the
regenerative braking is activated. The truckbrakes until it stops.
By moving the accelerator button (13) from one driving direction directly to the opposite direction,
the truck brakes regenerative until it starts traveling into the opposite direction.
The truck brakes, if the tiller is moved up or down to the braking zones (‘B’). If the tiller is released,
the tiller moves automatically up to the upper baking zone (‘B’).The truck brakes until it stops.
The safety (belly) button (1) prevents the operator from being crushed. If this button is activated, t
he
truck decel
erates and/ or starts traveling into the backwards direction (‘Bw.’) for a short distance and
stops. Please consider, that this button also operates, if the truckis not traveling and the tiller is in
the operating zone.
g. Malfunctions
If there are any malfunctions or the truck is inoperative, please stop using the truck and activate the
emergency button (5) by pushing it. If possible, park the truck on a safe area and press the X button of
pin-code panel. Inform immediately the manager and, or call your service. If necessary, tow the truck out
of the operating area by using dedicated towing/ lifting equipment.
h. Emergency
In emergencies or in the event of tip over (or off dock), keep safe distance immediately. If possible push
the emergency button (5). All electrical functions will be stopped.
7. PIN-CODE PANEL
BALLYPAL33N is equipped optional with a pin-code panel (3).
BALLYPAL45N is equipped standard with a pin-code panel(3)and three ID cards.
a.Introduction
Pin-code panel is an electronic system which is similar with an electronic alarm system. Truck will not
able to operate before typing a correct password, the main function is to prevent unauthorized operation.
b. Main parameters
Working voltage12V-60V