Installation Guide

-15-
OPTIONAL THERMOSTAT
A thermostat may help you maintain a constant house
temperature automatically. A millivolt thermostat is required.
A xed wall mount or a hand held model can be used. The
control panel can be set up two ways to operate your stove
in thermostat mode.
NOTE: YOUR THERMOSTAT SHOULD BE INSTALLED BY AN
AUTHORIZED DEALER OR SERVICE PERSON.
THERMOSTAT INSTALLATION
A MILLIVOLT THERMOSTAT IS REQUIRED.
Unplug stove from power outlet.
Remove control board from stove.
The two thermostat wires connect to the terminal block
on the lower left side of the back of the control board.
(See gure 14)
Insert the wires in the terminal side and tighten the two
screws.
MODES
TO SWITCH BETWEEN ANY OF THE THREE MODES THE STOVE
MUST BE SHUT OFF, THE NEW MODE SELECTED, AND THE STOVE
RESTARTED.
MANUAL MODE
USE THIS MODE EXCLUSIVELY IF YOU DO NOT CONNECT
AN OPTIONAL THERMOSTAT
In this mode the stove will operate only from the control
panel as detailed in the “OPERATION” section of this
owner’s manual.
HIGH/LOW THERMOSTAT MODE
USE THIS MODE ONLY IF YOU CONNECT A THERMOSTAT
When engaged in this mode the stove will automatically
switch between two settings. When warm enough, it will
switch to the #1 or low setting. The room air blower will
also slow to its lowest speed.
The Heat Level Advance setting on the bar graph will
stay where it was initially set. When the house cools
below the thermostat setting, the stove will switch to the
feed rate of the heat level advance setting.
ON/OFF THERMOSTAT MODE
USE THIS MODE ONLY IF YOU CONNECT A THERMOSTAT
In this mode when the home is warm enough the stove
will shut off. The fans will continue to run until the
stove cools.
When the home cools below the thermostat setting, the
stove will auto matically restart and run at the last feed
rate setting.
NOTE: When in “high/low” or “on/off” thermostat mode –
Do not operate the stove higher than the #3 setting.
Set damper control rod approximately ¼” to ½” out.
This will vary depending on elevation and weather
conditions. Observe stoves operation and adjust damper
as necessary.
THERMOSTAT INSTALLATION
On/Off High/Low
Manual
FIGURE 14