Installation Guide

© 2021 United States Stove Company
43
WARNING:
THE FIREPLACE AREA MUST BE KEPT CLEAR
AND FREE FROM COMBUSTIBLE MATERIALS,
GASOLINE AND OTHER FLAMMABLE VAPORS
AND LIQUIDS.
BURNER AND PILOT SYSTEM
The burner assembly may be removed for easier
access to the control compartment.
Performed by: Qualied Service Person
Frequency: Annually
Action:
Vacuum all components of the burner system.
Visually check burner ports for blockage,
especially near the pilot.
Visually check pilot light and burner ame pattern
when in operation. Flames should be steady, not
lifting or oating.
Burner Orifice
Burner Ports
FAN
CAUTION:
LABEL ALL WIRES PRIOR TO DISCONNECTION
WHEN SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND
DANGEROUS OPERATION. VERIFY PROPER
OPERATION AFTER SERVICING.
Performed by: Qualied Service Person
Frequency: Annually
Action:
Disconnect the fans from electrical current and
vacuum.
The bearings are sealed and require no oiling.
VENT SYSTEM
NOTE: If the vent-air intake system is disassembled
for any reason, reinstall per instructions provided
with installation (see Installation section).
Performed by: Qualied Service Person
Frequency: Annually
Action:
Examination of the vent system is required.
The ow of combustion and ventilation air must
not be obstructed.
MAINTENANCE