6.2 For the User
Symptom Cause What do do
Little or no water flows. The water supply is turned off. Turn on the main supply fully at the stop valve.
Cold water only -neon light
off.
The flow is not high enough to
activate.
Open the inlet service valve fully.
Water too cold -neon light
on.
The water flow rate is too high. Adjust the flow rate with hot water outlet
service valve.
The inlet water temperature has
dropped.
Adjust the flow rate with hot water outlet
service valve.
Water flow rate too low, or
temperature too high.
The main supply of water flow is
too low.
Increase the water flow.
The hot tap is not fully open. Adjust the stop/ball valve so that water is at the
right temperature with the tap fully open (see
section 5.2). Always turn the hot tap full on.
Water temperature
fluctuates.
Fluctuating water pressure and/or
flow is causing the flow switch to
cycle on and off.
Increase the flow rate.
Be sure that the isolation valves are properly
adjusted.
Be sure that the inlet filter screen is clean.
Be sure that the outlet restrictors and aeratots
on showers and/or faucets are clear.
Be sure that there is no plumbing crossover by
shutting off the inlet isolation valve and
opening an hot water outlets served by the AE
3.4/7.2/9.5. If there is a steady flow, then cold
water is flowing into hot water service lines and
back-pressuring the AE 3.4/7.2/9.5. This
condition must be fixed or the heater wil not
work properly.
Table 8