Specification
NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393
www.nicorlighting.com December 19, 2017 9:08 AM ADL6 Page 2 of 3
Photometric Data
ADL6 3500K 28W
Input Voltage (VAC) 120-277V
System Level Power (W) 31.3
Delivered Lumens (Lm) 2314
System Ecacy (Lm/W) 73.9
Correlated Color Temp (K) 3521
Color Rendering Index (CRI) 88
Beam Angle 80°
Spacing Criteria 1.16
ADL6 3500K 40W
Input Voltage (VAC) 120-277V
System Level Power (W) 41.2
Delivered Lumens (Lm) 3287
System Ecacy (Lm/W) 79.8
Correlated Color Temp (K) 3532
Color Rendering Index (CRI) 88
Beam Angle 80°
Spacing Criteria 1.16
ADL6 3500K 48W
Input Voltage (VAC) 120-277V
System Level Power (W) 49
Delivered Lumens (Lm) 3598
System Ecacy (Lm/W) 73.4
Correlated Color Temp (K) 3527
Color Rendering Index (CRI) 88
Beam Angle 80°
Spacing Criteria 1.16
Zonal Lumen Summary
Zone Lumens % of Luminaire
0-30 1050 45%
0-40 1597 69%
0-60 2121 92%
0-90 2314 100%
90-180 0 0.0%
0-180 2314 100%
Zonal Lumen Summary
Zone Lumens % of Luminaire
0-30 1491 45%
0-40 2261 69%
0-60 3014 92%
0-90 3287 100%
90-180 0 0.0%
0-180 3287 100%
Zonal Lumen Summary
Zone Lumens % of Luminaire
0-30 1603 45%
0-40 2429 68%
0-60 3262 91%
0-90 3598 100%
90-180 0 0.0%
0-180 3598 100%
Cone of Light Tabulation
Mounted height
(Feet)
Footcandles
Beam Center
Diameter
(Feet)
4 88.2 4.6
6 39.2 6.9
8 22.1 9.1
10 14.1 11.4
12 9.8 13.7
14 7.2 16.0
16 5.5 18.3
Cone of Light Tabulation
Mounted height
(Feet)
Footcandles
Beam Center
Diameter
(Feet)
4 125.3 4.6
6 55.7 6.9
8 31.3 9.1
10 20.0 11.4
12 13.9 13.7
14 10.2 16.0
16 7.8 18.3
Cone of Light Tabulation
Mounted height
(Feet)
Footcandles
Beam Center
Diameter
(Feet)
4 134.8 4.6
6 59.9 6.9
8 33.7 9.1
10 21.6 11.4
12 15.0 13.7
14 11.0 16.0
16 8.4 18.3
Intensity Summary
(Candle Power)
Angle Mean CP
0 1412
5 1402
15 1329
25 1184
35 889
45 437
55 197
65 117
75 58
85 12
95 0
Intensity Summary
(Candle Power)
Angle Mean CP
0 2004
5 1992
15 1889
25 1681
35 1248
45 632
55 279
65 164
75 83
85 18
95 0
Intensity Summary
(Candle Power)
Angle Mean CP
0 2157
5 2143
15 2034
25 1808
35 1338
45 693
55 319
65 198
75 104
85 23
95 0
CCT Data Multiplier
ADL6-1028-UNV-40K 1.022
ADL6-1028-UNV-50K 1.045
CCT Data Multiplier
ADL6-1040-UNV-40K 1.031
ADL6-1040-UNV-50K 1.063
CCT Data Multiplier
ADL6-1048-UNV-40K 1.031
ADL6-1048-UNV-50K 1.063
Fixture tested per LM-79-08. Photometric data is of the performance of a representative xture. Results may vary in the eld.
1418
1068
708
354
2006
1505
1003
502
2159
1619
1079
540