INSTALLATION MANUAL---Installation of the outdoor unit 
outdoor unit
remove
the upper
cover
screw
wiring diagram on the 
back of the cover
1. Take the cover away.
2. Connect the cable wires to the terminal board using 
 the same numbering as in the indoor unit.
3. For the electrical connections, see the wiring diagram 
 on the back of the cover
4. Fasten the cables with a cable-clamp.
5. An efficient earth connection must be ensured.
6. Replace the covers .
Screw the flare nuts to the outdoor unit coupling with 
the same tightening procedures described for the indoor 
unit.
connection pipes
flare nuts
liquid tap
gas tap
indoor unit
protection caps
liquid valve
gas valve
service port nut
To avoid leakage, pay attention to the following points:
1. Tighten the flare nuts using two wrenches. Pay atten-
 tion not to damage the pipes.
2. If the tightening torque is not sufficient , there will 
 probably be some leakage. With excessive tightening 
 torque there will also be some leakage, as the flange 
 could be damaged.
3. The surest system consists in tightening the connecti-
 on by using a fix wrench and a torque wrench:in this 
 case use the table on page 21.
vacuum pump
service port 
Air and humidity left inside the refrigerant circuit can 
cause compressor malfunction. After having connected 
the indoor and outdoor units, bleed the air and humidity 
from the refrigerant circuit by using a vacuum pump. 
19
ELECTRICAL CONNECTIONS
CONNECTING THE PIPES
BLEEDING