Certifications 2

NEVR-DULL
Safety Data Sheet
according to Regulation (EC) No. 1907/2006 (REACH)
GB - en
4/11
7.2. Conditions for safe storage, including any incompatibilities
Technical measures
:
Ground/bond container and receiving equipment.
Storage conditions
:
Store in a well-ventilated place. Keep cool. Keep container tightly closed. Store locked up.
Heat and ignition sources
:
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No
smoking.
Information about storage in one common storage
facility
:
Keep away from food, drink and animal feeding stuffs.
7.3. Specific end use(s)
Follow the directions!.
SECTION 8: Exposure controls/personal protection
8.1. Control parameters
Naphtha (petroleum), hydrotreated heavy (64742-48-9)
EU
Local name
White spirit Type 3
EU
IOELV TWA (mg/m³)
116 mg/m³
EU
IOELV TWA (ppm)
20 ppm
EU
IOELV STEL (mg/m³)
290 mg/m³
EU
IOELV STEL (ppm)
50 ppm
EU
Notes
skin. (Year of adoption 2007)
EU
Regulatory reference
SCOEL Recommendations
Naphtha (petroleum), hydrotreated heavy (64742-48-9)
DNEL/DMEL (Workers)
Acute - systemic effects, inhalation
1300 mg/m³
Acute - local effects, inhalation
1100 mg/m³
Long-term - local effects, inhalation
840 mg/m³
DNEL/DMEL (General population)
Acute - systemic effects, inhalation
1200 mg/m³
Acute - local effects, inhalation
640 mg/m³
Long-term - local effects, inhalation
180 mg/m³
Solvent naphtha (petroleum), light arom. (64742-95-6)
DNEL/DMEL (Workers)
Acute - systemic effects, inhalation
1300 mg/m³
Acute - local effects, inhalation
1100 mg/m³
Long-term - local effects, inhalation
840 mg/m³
DNEL/DMEL (General population)
Acute - systemic effects, inhalation
1200 mg/m³
Acute - local effects, inhalation
640 mg/m³
Long-term - local effects, inhalation
180 mg/m³
8.2. Exposure controls
Appropriate engineering controls:
Ensure good ventilation of the work station.
Hand protection:
In case of repeated or prolonged contact wear gloves. EN 374. Choosing the proper glove is a decision that depends not only on the type of
material, but also on other quality features, which differ for each manufacturer. Please follow the instructions related to the permeability and the
penetration time provided by the manufacturer. Gloves must be replaced after each use and whenever signs of wear or perforation appear
Eye protection:
Chemical goggles. EN 166