User manual

INSTRUCTIONS FOR USE
Lime protection Multi PLUS
Dear customer,
Thank you for your purchase of this product.
Prior to using this device, it is recommended that you carefully read the Instructions for Use.
Warning!! Important safety information!!
- No liquids of any kind must be allowed to penetrate this device.
- The device must never be operated under adverse environmental conditions. Adverse environmental conditions include:
ambient temperatures above 50° C, flammable gases, solvents, vapors, dust, relative humidity above 80 %, wetness.
- The device may only be operated in dry and enclosed areas.
- If it can be assumed that a safe operation is no longer possible, then the device must be stopped and switched off immediately,
and preventive measures against an unintentional operation must be taken.
A safe operation of the device can no longer be assumed if the device no longer provides any indication of functionality, if it
shows visible signs of damage, if the electricity supply cable is damaged, in the event of transportation damage, or after the
device has been stored under harmful conditions.
- Maintenance and repairs – maintenance and repair services may only be performed by authorized experts. Only certified spare
parts may be used as replacements.
Functionality description
This magnetic field generator Multi PLUS offers effective protection against limescale deposits in water pipe systems and all
connected appliances. Existing limescale deposits are gradually dissolved and rinsed away. This does not impair the quality of the
water. Stubborn limescale deposits are gently removed by the various frequencies up to 25 kHz and a special program.
No intervention into the pipe system is necessary since the electromagnetic waves work from the outside on the calcium carbonate
particles in the water.
The basic structure of the lime is being changed by the electromagnetic waves in such a way that no solid deposits have a chance
to develop again. This is not only ecologically beneficial but also environment-friendly as no chemical substances of any kind are
being used.
The lime protection Multi PLUS device is appropriate for all degrees of water hardness and can be adjusted individually. As a result
of lime-free heating systems, you will also be able to reduce the energy requirements and the amount of detergents and
dishwashing agents used.
This device is intended for use in households with a water consumption of up to 5m³/h.
Note! Attention!! You can achieve the best possible efficiency of the device in “automatic” mode as all programs are executed
successively. If your pipe systems are already badly affected by limescale, we recommend that you use the device for 8 to 14
months in “pipe repair” mode in order to dissolve the limescale deposits more quickly. In this mode the maximum frequency is 25
kHz.
In the initial period, clean the shower heads and sprinkler fittings in water taps more frequently, as loosened limescale particles can
impede the flow of water. Your lime protection Multi PLUS is maintenance-free.
Correct usage: The device is designed exclusively for the dissolution and prevention of limescale deposits in water pipe systems.
The magnetic field generator Multi Plus is suitable for all pipe systems (plastic and metal).
Installation
The installation location should be selected so that the device can be installed directly at the main water connection of the building
or apartment. The installation should be made on a section of free pipe with a length of at least 25 cm, without sleeves etc. Also,
please make sure that there is a 230 V power outlet nearby. If there is a built-in filter, then the installation should be made ahead of
the filter
You need to make sure that there is enough space – approximately 7 to 10 cm – for the coil (taping wire) to the left and to the right
of the installed multi-lime prevention device. Attach the multi-lime prevention device to the wall above the pipe.
Warning!!
Be sure to disconnect the mains power plug prior to opening the device. If in doubt, please consult an expert.
Unscrew the four screws on the top of the device and remove the upper shell.
For wall mounting, there are four recesses that you need to punch through.
Please close the device again after it has been mounted to the wall. Now, wind the wire that protrudes from the left and right side of
the device carefully and tightly side by side around the pipe.
Important notice!! Make sure that the winding direction of the two wires is identical; otherwise, the effectiveness of the device
might be impaired. In order to set the windings, you should use adhesive tape or hot glue.
Warning!! When winding wire
around metal pipes, make sure
that the bare wire ends are not
in contact with the pipe. If this
should happen, the “Error” LED
will be illuminated when the
device is started up.
Water pipe
!!Wind wire very tightly!!
Lime
p
rotection