Certifications 2
Safety data sheet in accordance with regulations (EC) No. 1907 / 2006 and (EC) No. 1272 / 2008
Product name: Eurolite Smoke fluid "B", "C", "P", "E" , "X"
8.2.
Exposure controls
Handle in accordance with good industrial hygiene and safety practice.
Wash skin thoroughly after handling with plenty of soap and water.
Eye/face protection: Recommended during refilling.
Hand protection: Wear gloves when refilling.
Suitable gloves are:
Natural rubber/Natural latex - NR (0,5 mm)
(use non-powdered and allergen free products)
Polychloroprene - CR (0,5 mm)
Nitrile rubber/Nitrile latex - NBR (0,35 mm)
Butyl rubber - Butyl (0,5 mm)
Fluoro carbon rubber - FKM (0,4 mm)
Polyvinyl chloride - PVC (0,5 mm)
Body Protection: The protection clothing should be solvent resistant.
Respiratory protection:
not mandatory
not mandatory
9. Physical and chemical properties
9.1.
Information on basic physical and chemical properties
Smoke fluid
Diethylene glycol )
1
a) Appearance: Form: liquid Form: liquid
Colour: colourless Colour: colourless
b) Odour: neutral odourless
c) Odour threshold: Data not available
d) pH 6 … 8 6 … 8 at 20 °C
Concentration:
200 g/l
e) -8 °C to -43 °C -6 °C
f) from 100 °C 244 °C
g) Flash point: > 140 °C 138 °C open cup
h) Evaporation rate: Data not available < 0,01 (Butyl acetate = 1)
i) Flammability: Data not available 335 °C
Temperature class:
T2
Explosion group: IIB
j) Data not available
l.e.l.:
1,7 Vol.-% 75 g/m³
u.e.l.:
37,0 Vol.-% 1635 g/m³
k) Vapour pressure: Data not available 0,008 hPa at 25 °C
l) Vapour density: Data not available 3,66 (Air = 1,0)
m)
Relative density: 1,00 at 20 °C and 1013 hPa
n) Solubility(ies): miscible in water entirely mixable
o) Data not available log K
ow
: - 2,0
p) Auto-ignition temperature: Data not available 372 °C at 1013 hPa
q) Decomposition temperature: Data not available 372 °C at 1013 hPa
r) Viscosity: low viscosity V
dyn
: 30 mPa*s at 20 °C
Conversion: V
kin
= V
dyn
/ Density
s) Explosive properties: Data not available
t) Oxidising properties: Data not available Data not available
9.2. Other information
Conductivity: < 5 µS/cm < 0,5 µS/cm
Densitiy 1,02 g/ml 1,12 g/ml at 20 °C
Upper/lower
flammability or explosive
Partition
If, according to a hazard assessment, the limit values can not be excluded by aerosol and
fogging, a respiratory protection device must be provided: gas filter A, color code brown
Initial boiling point
Melting point/
Additional
Components of
The product is not explosive,
but formation of explosive air /
vapor mixtures is possible
Use by official standards (NIOSH, EN 166) tested and approved equipment.
Revision: 19.06.2017
Printing date: 19.06.2017
All previous data sheets will be replaced by this version and immediately lose their validity
Page 5 of 8
Version 6.0