Datasheet

JACKCON Electrolytic Capacitors
12.
Solderability
test
After the lead wire fully immersed in the solder for 2±0.1 sec at a temperature of
245±2℃, the solder coating must be more then 95%
13.
Mechanical
1. The test is about lead tabs strength.
2. Tension test:
The lead tabs shall not be broken or any malformed condition after fixing
capacitor vertically and pressing the following weight on the lead tabs of capacitor
for 10±1 sec.
Lead tabs diameter(mm) Weight(Kg)
0.5
0.5
0.6~0.8 1.0
>0.8 2.5
3. Bending test:
The capacitor is held in vertical position. Attach a weight to the lead tabs, slowly
rotate the capacitor 90°to a same way in the opposite direction. Repeat it again (5 secs
per cycle). The lead tabs shall not be broken or cracked.
Lead tabs diameter(mm) Weight(Kg)
0.5
0.5
0.6~0.8 1.0
>0.8 2.5
14. Safety vent
Condition: Apply a reverse voltage with current 1 amp.(DC reverse voltage test)
Criteria: When the pressure relief vent operated, the capacitor shall not flame although
gas generation or expulsion of a part of the inside element is allowable.
If the vent does not operate with the voltage applied for 30 minutes, the test is
Considered to be passed.
15. Standards
Satisfies Characteristic W of IEC-60384-4,18
P.4 FM0754B-4