Datasheet

JACKCON Electrolytic Capacitors
Capacitance
change
Within ±10% of the initial
value
TANδ
Within specified value
Leakage
Current
Within specified value
9. Low
temperature
test
Capacitor are place at -40±3 for 72±
4hrs.And then the capacitor shall be
subjected to standard atmospheric
conditions for 16 hours, after witch
measurements shall be made.
Physical no broken and undamaged
Capacitance
change
Within ±10% of the initial
value
TANδ
Within specified value
Leakage
Current
Within specified value
10. Vibration
test
1. Fix it at the point 4mm or less form
body. For ones of 12.5mm or 25mm
or more length, use separate fixture.
2. Direction and during of vibration:3
orthogonal direction each for 2hrs
total 6hrs.
3. Mutually frequency:
10 to55Hz reciprocation for 1 min.
4.Total amplitude:1.5mm
Physical no broken and undamaged
Capacitance
change
Within ±10% of the initial
value
TANδ
Within specified value
Leakage
Current
Within specified value
11. Reflow test 1. IR Reflow
Temp (T1~T2)
100~150
Preheat
Time (t1) max 40 sec
Temp(T3)
260
Duration
Time (t2) max
10 sec
Temp(T4)
270
Peck
Time (t3) max
5 sec
Reflow
cycle
Twice or less
2. Solder bath method:
Solder temperature:260±3
Immersion time:5+1/-0 sec
Thickness of heat shunt
(Printed wiring board):1.6mm
3. Soldering iron method:
Bit temperature: 350±10℃
Application time of soldering
Iron:3+1/-0 sec
Physical no broken and undamaged
P.3 FM0754B-4