SDS

Section 13. Disposal considerations
Waste Disposal Method: Hazardous waste. Can be incinerated, when in
compliance with local regulations.
Contaminated Packaging: Empty containers should be taken for local recycling,
recovery or waste disposal.
US EPA Waste Number: D001 (IGNITABLE): When discarded in its purchased form,
this material would be regulated under 40 CFR 261.21 as EPA Hazardous Waste
Number D001 based on the characteristic of ignitability.
Section 14. Transport information
DOT
UN-No UN1866
Proper Shipping Name: RESIN SOLUTION
Hazard Class CLASS 3
Packing Group PGIII
NAERG: 127
TDG
UN-No UN1866
Proper Shipping Name RESIN SOLUTION
Hazard Class CLASS 3
Packing Group PGIII
NAERG: 127
IATA
UN-No UN1866
Proper Shipping Name RESIN SOLUTION
Hazard Class CLASS 3
Packing Group PGIII
NAERG: 127
IMDG/IMO
UN-No UN1866
Proper Shipping Name RESIN SOLUTION
Hazard Class CLASS 3
Packing Group PG III
EmS No. F-E, S-E
Section 15. Regulatory information
Clean Air Act -Hazardous Air Pollutants (HAP): The following chemical(s) are
listed as hazardous air pollutants (HAP) under the U.S. Clean Air Act
Section 112(b)(1), (40 CFR 61):
STYRENE MONOMER [1] (CAS# 000100-42-5),
METHYL METHACRYLATE [1] (CAS# 000080-62-6)
See Section 2 of this SDS for amount.
Clean Water Act - Priority Pollutants (PP):
STYRENE MONOMER [1] (CAS# 000100-42-5),
METHYL METHACRYLATE [1] (CAS# 000080-62-6)
is listed under Section 311 as a Hazardous Substance.
Occupational Safety and Health Act (OSHA): This material is classified
as a hazardous chemical under the criteria of the US Occupational Safety and
Health Administration (OSHA) Hazard Communication Standard, 29 CFR 1910.1200.