Datasheet

Page 7 of 7 QR-QE-20/2003.08.01
5
Contact
resistance
接觸阻抗
Less than 100 mΩ
低於 100 mΩ
Apply 2 times of the operating force of the
static load on the vertical direction of the
lever, measure the resistance by using the
Contact Resistance Tester with 1KHZ,
20mV, 5~50mA of current.
將兩倍於作動力之靜負荷加於操作柄之
中央以(1KHZ,20mV, 5~50mA)微電流接觸
阻抗計測定.
6
Insulation
resistance
絕緣阻抗
More than 100 MΩ
100 MΩ以上
A voltage of DC100V is applied between
terminals.
DC100V
之電壓加於端子間測定
.
7
Withstand
voltage
耐電壓
There shall be no damage, arc or
dielectric breakdown.
無絕緣破壞之現象
A voltage of AC 250V(50~60HZ) shall be
applied for 1 min between terminals.
AC250V(50~60HZ)電壓施加於端子間1
分鐘.
8
Rated power
額定功率
12 V DC 50 mA
Within 70
小於 70
9
Number of
cycles
開關耐久次數
Contact resistance 200mΩMAX,
No mechanical malfunction.
接觸阻抗最大 200mΩ,
機械方面能動作.
100,000 Cycles min
Other Cycles min
五、General 一般事項
序號
NO.
ITEM
Unless otherwise specified, test and measurement should be carried out in following condition:
如無特殊要求,試驗與測試將按以下條件進行:
Ambient temperature
溫度
15°C to 35°C
Relative humidity
相對濕度
25% to 75%
1
Air pressure
氣壓
86 KPa to 106 KPa
2
Operating temperature range
使用溫度範圍
-10°C to +70°C
3
Storage temperature range
儲存溫度範圍
-30°C to +80°C
Approved
核 准
Q.I.Department
審 查
Design dept.
經 辦 者
倪艷麗