Datasheet
BCM SENSOR TECHNOLOGIES BVBA
Brechtsebaan 2
B-2900 Schoten - Antwerpen, BELGIUM
Industriepark Zone 4,
Tel.: +32-3-238 6469
Fax: +32-3-238 4171
website: www.bcmsensor.com
email: sales@bcmsensor.com
The listed specifications are subject to change without prior notice.
environment protection
refer to the dimensions on the datasheets
Specifications
Units
Parameter
150
%fs
safe load limit
200
%fs
ultimate overload
3.3
mV/V
output sensitivity at fs
≤ ±0.5
mV
zero unbalance
≤ ±0.5 (standard), ≤ ±1
%fs
accuracy
5, ..., 25
Vdc
excitation
0.1, 0.2, 0.3, 0.5, 0.7, 1, 2, 3, 5, 7, 10, 20, 30, 50
kg
capacity
30
Vdc
max. excitation voltage
11 ±2
9.5 ±2
kΩ
kΩ
input resistance
output resistance
≥100 @50Vdc
MΩ
insulation resistance
-25 ~ +85
°C
storage temp. range
-25 ~ +85
°C
operating temp. range
-20 ~ +55
°C
compensated temp. range
≤ ±0.02
%fso/°C
temp. coefficient of zero
ceramics (96% Al2O3)
load cell body material
±0.02
%fs
creep error (30 min.)
4 solder pads
mechanical interface
IP65
electrical interface
~1
g
unit weight
≤ ±0.02
%fso/°C
temp. coefficient of span
Technical Data
Model 1531
Ceramic Tension Force Transducers