Pulse width
Polarity positive, negative
Functions equal, not equal, lower, higher, within/
without a range
Pulse duration 32ns to 17s, resolution min. 8ns
Sources all analog channels
Logic
Functions
boolean operators AND, OR, TRUE, FALSE
time based operators
equal, not equal, lower, higher, within/
without a time range, timeout
Duration 8 ns to 2 s, resolution min. 1 ns
States H, L, X
Sources all logic and analog channels
Video
Sync. pulse polarity positive, negative
supported standards NTSC, SECAM, PAL, PAL-M, SDTV 576i,
HDTV 720p, HDTV 1080i, HDTV 1080p
Field even/odd, either
Line line number selectable, all
Sources all analog channels, external (AC, DC)
Serial Busses (R&S®HOO10/11/12)
Bus representation
Up to two busses can be analyzed at the
same time. Color-coded display of
decoded data in ASCII, binary, decimal
and hexadecimal format.
Option / Voucher code
R&S®HOO10/R&S®HV110
Analysis of I
2
C, SPI, UART/RS-232 signals
on analog and logic channels
R&S®HOO11/R&S®HV111
Analysis of I
2
C, SPI, UART/RS-232 signals
on all analog channels
R&S®HOO12/R&S®HV112
Analysis of CAN and LIN signals on
analog and logic channels
Trigger types by protocols
I
2
C Start, Stop, ACK, NACK, Address/Data
SPI Start, End, Serial Pattern (32 Bit)
UART/RS-232 Startbit, Frame Start, Symbol, Pattern
LIN
Frame Start, Wake Up, Identifier, Data,
Error
CAN
Frame Start, Frame End, Identifier, Data,
Error
Horizontal System
Time domain (Yt) main screen, time domain and zoom
window
Frequency domain (FFT) time domain and frequency domain
window (FFT)
XY/XYZ mode voltage (XY), intensity (Z)
VirtualScreen virtual display of 20 Div for all math,
logic, bus, reference signals
Component tester voltage (X), current (Y)
Reference signals up to 4 references
Channel deskew -15 ns to +16 ns, step size 1 ns
Memory Zoom up to 50.000:1
Time base
Accuracy 50.0 x 10
-6
Aging 10.0 x 10
-6
per year
Operation Modes
REFRESH 2 ns/Div to 50 s/Div
ROLL 50 ms/Div to 50 s/Div
Acquisition System
Realtime Sampling Rate
Analog channels 4 x 1 GSa/s or 2 x 2 GSa/s
Logic channels 8 x 1 GSa/s
Memory depth 4 x 1 MPts or 2 x 2 MPts
Resolution 8 Bit, (HiRes up to 10Bit)
Waveform arithmetics
refresh, roll (loose/triggered), average (up
to 1024), envelope, peak detect (1 ns),
filter (low-pass, adjustable), high
resolution (up to 10 Bit)
Record modes automatic, max. sampling rate, max.
waveform rate
Interpolation
all analog channels sin(x)/x, linear, sample-hold
logic channels pulse
Delay
pre-trigger 0 to 8 x 10
6
Sa x (1/sample rate)
post-trigger 0 to 2 x 10
6
Sa x (1/sample rate)
Waveform update rate up to 2,000 Wfm/s
Waveform display dots, vectors, persistence afterglow
Persistence afterglow min. 50 ms
Waveform measurements and Operation
Operation menu-driven (multilingual), auto-set, help
functions (multilingual)
Automatic measurements
voltage (V
pp
, V
p+
, V
p-
, V
rms
, V
avg
, V
min
, V
max
),
amplitude, phase, frequency, period, rise/
fall time (80%, 90%), pulse width (pos/
neg), duty cycle (pos/neg), standard
deviation, delay, crest factor, edge/pulse
count (pos/neg), trigger period, trigger
frequency
Automatic search functions Edge, pulse, peak, rise/fall time, runt
Cursor measurements
voltage (V1, V2, ∆V), time (t1, t2, ∆t,
1/∆t), ratio X, ratio Y, pulse and edge
count (pos/neg), peak values (V
pp
, V
p+
,
V
p-
), mean/RMS/standard deviation, duty
cycle (pos/neg), rise/fall time (80%, 90%),
ratio marker
Quick measurements (QUICKVIEW)
voltage (V
pp
, V
p+
, V
p-
, V
rms
, V
mean
), rise/fall
time, frequency, period plus 6 additional
measurement functions (see automatic
measurement functions, freely selectable)
Marker
up to 8 freely positionable markers for
easy navigation, automatic marker
positioning based on search specification
Frequency counter (hardware based)
Resolution 6 digit
Frequency range 0.5 Hz to 70/100/150/200 MHz
Accuracy 50.0 x 10
-6
Aging ±10.0 x 10
-6
per year
Mask Testing
Functions Pass/Fail comparison with an user-definied
mask performed on waveforms
Sources all analog channels
Mask definition Mask enclosing acquired waveform with
user-defined tolerance
Actions
on mask violations
beep, acquisition stop, screenshot,
trigger pulse, automatically saving trace
data
during acquisiton
Statistics: number of completed tests
(max. 4x10^9 events), number of passes
/ failed acquisitions (absolute and in