Datasheet
Item Specified limits Test Method and Conditions
4-1.
high temperature storage
△R25≤±1%
△B25/50≤±1%
85℃,1000hours
4-2.
low temperature storage
△R25≤±1%
△B25/50≤±1%
-40℃,1000hours
4-3.
High humidity storage
△R25≤±1%
△B25/50≤±1%
60℃ and 95%RH, 1000hours
4-4.
temperature cycle test
△R25≤±1%
△B25/50≤±1%
-20℃,keep 20minutes then 25℃, keep 5
minutes and then 85℃,keep 20 minutes,
circulate 1000 times like this
5、STRUCTURE AND DIMENSIO
Distributed by Conrad Electronic, Hirschau, Germany
2
6
Φ5±0.1
1 2 3 4
Sym Name pecified Limits Material
1 Thermistor MJD-502-3470-1
2 Under Coating Insulation material (elastical)
3
Filling Resin Epoxy Resin
4 Case Stainless steel shell
5
Lead Wire
UL AWM2651, 26AWG, VW-1, temperature
105 ° C, voltage 300V (Black)
6
Connector XH2.54-2 Type Terminal
5
25±0.5mm
600±10mm