Energy Guide
Master Contract: 229828
Report: 70024182
Project: 70024182
Client: Guangde Ledup Enterprise, Inc
Attachment 1
No. 10, Ke Yan Road, Confidential Telephone: 86-20-32053102
Guangzhou Science Park, Fax: 86-20-87320306
Guangzhou, 510663, China
www.csagroup.org Page 11 of 15
Over-Voltage:
Prior to testing, operate three decorative light strings for a 24 hour (± 1%) seasoning period at 120 V ± 1 V RMS AC.
Energize the light string at 132 V ± 1 V RMS AC for one hour and examine for failure. Count any lamps that have failed
(as per definition below). Calculate the failed lamps as a percentage of total lamps on the three strings.
A lamp has failed if the light output is less than half the expected output for a comparable lamp of the same age in good
condition. This will normally be determined by comparison with a good lamp of the same color on the same string.
Equipment No. / Cal. Due.Date
Commencing Date
Complete Date
Tested by
JV60266-004/ 2015-10-22 2015-03-16 2015-03-17 Marco Xu
Tested Model Sample ID Number of Failed Lamps Percentage of Failed Lamp
RGB120/25L
GZ20150309007-001
0
0%
GZ20150309007-002
0
0%
GZ20150309007-003
0
0%
RGB120/50L
GZ20150309007-004
0
0%
GZ20150309007-005
0
0%
GZ20150309007-006
0
0%
RGB120/100L
GZ20150309007-007
0
0%
GZ20150309007-008
0
0%
GZ20150309007-009
0
0%