B. Electrical Requirement:
Input Power:
Prior to testing, operate three decorative light strings for a 24 hour (± 1%) seasoning period at 120 V ± 1 V RMS AC.
Measure input power and current at 120 V ± 0.5 V RMS AC. For light string systems with power adapters or controllers
that can accommodate multiple light strings, the input power shall be measured with the rated maximum number of strings
attached. Divide the measured input power by the number of lamps on the tested string to calculate the input power
consumption per lamp.
The input power consumption per lamp on each of the three strings in the sample shall not exceed 0.20 watts.
Equipment No. / Cal. Due.Date
Commencing Date
Complete Date
Tested by
JV60266-004/ 2015-10-22 2015-03-13 2015-03-13 Marco Xu
Tested Model
Sample ID
GZ20150309007
Input
Voltage (V)
Input
Frequency(Hz)
Input Current
(mA)
Input Wattage
(W)
Input Power Per
Lamp (W)
RGB120/25L
-001
120.13
60
33.25
1.550
0.06
-002
120.13
60
32.49
1.541
0.06
-003
120.13
60
34.82
1.563
0.06
RGB120/50L
-004
120.13
60
47.60
2.435
0.05
-005
120.13
60
48.27
2.482
0.05
-006
120.13
60
47.33
2.417
0.05
RGB120/100L
-007
120.13
60
74.27
3.931
0.04
-008
120.13
60
73.90
3.870
0.04
-009
120.13
60
73.25
3.837
0.04