Master Contract: 229828 Report: 70024182 Project: 70024182 Client: Guangde Ledup Enterprise, Inc Attachment 1 ENERGY STAR® Program Requirements Product Specification for Decorative Light Strings, Version 1.5 Report prepared for: Guangde Ledup Enterprise, Inc Jingtang Road Economic Development Zone Guangde, Anhui 242200, China CSA Report Number: 229828-70024182 Report Date: May 21, 2015 Model Tested: Model RGB120/25L, RGB120/50L and RGB120/100L.
Master Contract: 229828 Report: 70024182 Project: 70024182 Client: Guangde Ledup Enterprise, Inc Attachment 1 TABLE OF CONTENTS Product Description ................................................................................................................................................ 3 Test Overview ......................................................................................................................................................... 5 Summary of Tests Result .....................
Master Contract: 229828 Report: 70024182 Project: 70024182 Client: Guangde Ledup Enterprise, Inc Attachment 1 Product Description The product submitted for evaluation is as follows: Indoor and outdoor use, decorative LED lighting string, with Class 2 output LED driver and controller, Model RGB120/25L, RGB120/50L and RGB120/100L. Rating of Lighting String: Lighting String Model RGB120/25L RGB120/50L RGB120/100L 1. 2. 3. 4. Total Number of Lamps of the Lighting String 25 50 100 Rated Input Current (A) 0.
Master Contract: 229828 Report: 70024182 Project: 70024182 Client: Guangde Ledup Enterprise, Inc Attachment 1 Photo of the Product No. 10, Ke Yan Road, Guangzhou Science Park, Guangzhou, 510663, China www.csagroup.
Master Contract: 229828 Report: 70024182 Project: 70024182 Client: Guangde Ledup Enterprise, Inc Attachment 1 Test Overview The Decorative Lighting Strings Samples were evaluated in accordance with ENERGY STAR® Program Requirements Product Specification for Decorative Light Strings, Version 1.5 An Integrating Sphere was used to measure all photometric characteristics of the sample. A full description of these and the associated equipment is provided at the end of this report.
Master Contract: 229828 Report: 70024182 Project: 70024182 Client: Guangde Ledup Enterprise, Inc Attachment 1 Summary of Tests Result – Criteria Item ENERGY STAR Requirements Sample Size/Specific Requirements All decorative light strings attached to a decorative form shall be ENERGY STAR qualified for their intended end use on the decorative form and meet all applicable electrical safety requirements for their intended use.
Master Contract: 229828 Report: 70024182 Project: 70024182 Client: Guangde Ledup Enterprise, Inc Attachment 1 Summary of Tests Result – (Con’t) Criteria Item ENERGY STAR Requirements Sample Size/Specific Requirements Measured Test Data Verdict B. Electrical Requirements Input Power Over-Voltage The input power consumption per lamp on each of the three strings in the sample shall not exceed 0.20 watts. For decorative light strings that modulate in their power use (e.g.
Master Contract: 229828 Report: 70024182 Project: 70024182 Client: Guangde Ledup Enterprise, Inc Attachment 1 Summary of Tests Result – (Con’t) Criteria Item ENERGY STAR Requirements Sample Size/Specific Requirements Measured Test Data Verdict E. Product Packaging for Consumer Awareness Requirements Product Suitability Product Description Correlated Color Temperature for White-light Strings Packaging shall state product’s suitability for use indoor-only or indoor/outdoor use.
Master Contract: 229828 Report: 70024182 Project: 70024182 Client: Guangde Ledup Enterprise, Inc Attachment 1 Test Data: A. Inspection: Model No. RGB120/25L Sample ID GZ20150309007 -001 -002 -003 No. 10, Ke Yan Road, Guangzhou Science Park, Guangzhou, 510663, China www.csagroup.
Master Contract: 229828 Report: 70024182 Project: 70024182 Client: Guangde Ledup Enterprise, Inc Attachment 1 B. Electrical Requirement: Input Power: Prior to testing, operate three decorative light strings for a 24 hour (± 1%) seasoning period at 120 V ± 1 V RMS AC. Measure input power and current at 120 V ± 0.5 V RMS AC.
Master Contract: 229828 Report: 70024182 Project: 70024182 Client: Guangde Ledup Enterprise, Inc Attachment 1 Over-Voltage: Prior to testing, operate three decorative light strings for a 24 hour (± 1%) seasoning period at 120 V ± 1 V RMS AC. Energize the light string at 132 V ± 1 V RMS AC for one hour and examine for failure. Count any lamps that have failed (as per definition below). Calculate the failed lamps as a percentage of total lamps on the three strings.
Master Contract: 229828 Report: 70024182 Project: 70024182 Client: Guangde Ledup Enterprise, Inc Attachment 1 C. Output and Reliability Test: Prior to testing, operate three decorative light strings for a 24 hour (± 1%) seasoning period at 120 V ± 1 V RMS AC. Assemble the three decorative light strings into three flat test configurations. For each, wrap the string around a rigid board or frame so that all are mechanically supported and oriented with the lamps directed outward.
Master Contract: 229828 Report: 70024182 Project: 70024182 Client: Guangde Ledup Enterprise, Inc Attachment 1 D. Weathering Requirement: Prior to testing, operate three decorative light strings for a 24 hour (± 1%) seasoning period at 120 V ± 1 V RMS AC. Assemble the three decorative light strings into three flat test configurations. For each, wrap the string around a rigid board or frame so that all are mechanically supported and oriented with the lamps directed outward.
Master Contract: 229828 Report: 70024182 Project: 70024182 Client: Guangde Ledup Enterprise, Inc Attachment 1 Photometric Testing Information The sample was evaluated for photometric and electrical characteristics using an integrating sphere, each located in purpose-built, temperature and humidity-controlled, draft free environments. The integrating sphere is a 2-meter diameter sphere manufactured by EVERFINE (Model# 2.
Master Contract: 229828 Report: 70024182 Project: 70024182 Client: Guangde Ledup Enterprise, Inc Attachment 1 EQUIPMENTS STATUS 仪器设备使用记录 Used In This Project 本次测试使用 JV Number JV 编号 Description 仪器名称 Manufacturer 生产商 Model 型号 Calibration Due Date 校准日期 0.