User manual

7
Maintenance
The device is completely maintenance-free. Use exclusively a dry cleaning cloth for cleaning. Solvents or
sharp-edged tools must not be used.
Troubleshooting
Fault Possible cause Remedy
After the pump switches on,
the time it takes till hot water
is available at the various taps
differs, sometimes by many
minutes
Controller switches off
although hot water has not
yet been supplied to all taps
Fault in the piping system:
No optimum cross-
sections in partial circuits
or bypasses exist in the
system
Pump capacity too low
Let controller operate
without return sensor:
Switch off pump after a
fixedly set time
Use pump with a greater
capacity
Pump switches on during
heating up of the water in the
hot-water storage tank
although no tap has been
turned on
Flow sensor arranged too
close to the hot-water
storage tank. Heat contact
to storage tank too close
Hot-water storage tank
heats up very fast
Install flow sensor at a
point located farther away
from storage tank
Do not make any changes
(if no water is withdrawn,
the storage tank will also
be heated only infrequent-
ly; an additional circula-