User manual
9
Fault Possible cause Remedy
storage tank
• No LED display
• Pump does not start although
yellow LED lights
• Program run has been
disturbed by short
disturbances in the power
supply grid.
• Defect, e.g. after
overloading
• Disconnect basic device
for a few seconds from
socket outlet.
• Return device to
manufacturer for repair
• Pump switches on again
shortly after deactivation
• Deactivation criteria are
already detected in the
hot-water circuit while the
activation criteria are still
active
• No changes required, the
controller automatically
corrects the erroneous
information
Technical data
Mains voltage 230 V AC 50 Hz (own power consumption max. 0.5 W)
Permissible output current max. 1.6 A
Dimensions (LxWxH) 86 mm x 56 mm x 45 mm
Sensor connection leads 2x2.5 m with one connector each
Protective quality to DIN VDE 0701