User manual

Either:
ST2: 12 Volt DC voltage, +, -
or:
ST3: 230 Volt AC voltage, L1, N
1: Antenna
J1: Jumper
D2: System LED, green
D12: Display “relay on active”, red
SW1: Key
ST1: Terminals load
Teaching in
In order to teach in, please briefly press the key (SW1) first. This is confirmed by a flashing of the system LED (D2). Now, press any key of a
transmitter to teach it in. If the transmitter signal is recognized correctly the system LED goes out. If the transmitter has already been taught
in, the teaching-in process stops. If no transmitter signal is recognized within 20 seconds, the teaching-in process stops and the LED goes
out.
A maximum of 10 transmitters can be taught in, when teaching in an 11
th
transmitter the first one taught in will be overwritten, etc.
If necessary, all taught-in transmitters can be erased by pressing the key (SW1) for approx. 10 seconds. The completed erasing process is
indicated by the illuminated LED as long as the key is still pressed.
In the event of power failure, transmitter data once taught in remain in the storage of the microcontroller.
Regular operation
A correctly recognized transmitter signal is indicated by rapid flashing of the system LED, no matter whether the transmitter has been taught
in or not.
If a known transmitter signal is received, the corresponding action is triggered, i.e. the selected relay is activated or deactivated (lock-in
operation). Keying operation may be pre-selected for the relay by the jumper. In this case the relay will pull up for 1 second and then fall
again when the transmitter key belonging to it is operated, regardless of how long the key remains pressed.
This reprogramming can also be done during operation, i.e. power supply must not be stopped.
Jumper clip disconnected = lock-in operation
Jumper clip plugged in = key operation
The switching mode of the relays can be checked by the LED’s (12) positioned before.
Connection
The consumers are connected with the terminals positioned directly before the relays. Each connection on the right side is the common
double-throw contact C, the terminal in the middle is the break contact (COM) and the left one is the make contact (NO).
Any electrical direct or alternating current consumers may be connected as load. Please pay attention to connect cable and terminals safely,
in particular when connecting power supply. Each consumer must be fitted with its own fuse.
Maximum connected load: 230V 8A~ or 30V 10A=
Technical specifications
Output: double-throw contact max. 230V 8A ~
Input power supply: 12 Volt DC = max. 200mA or 230 Volt AC
Power supply transmitter: lithium round cell CR2032
Dimensions receiver: approx. 100 x 40 x 85 mm
Weight transmitter: approx. 40g
Temperature range: 0°C – 40°C
GB Environmental protection information
When no longer in use, this product may not be deposited in the normal household waste but should be brought to a
collection point for the recycling of electrical and electronic appliances. A symbol on the product, the operating instructions
or the packaging draws attention to this.
The materials are recyclable as marked. By re-use, recycling or another form of using old appliances you are making an
important contribution towards the protection of the environment.
Please ask your local authorities for the appropriate disposal point.
Subject to technical modifications. We assume no liability for typographical errors. 11/2005