R I C H F O R M
T I T A N I U M
Item Unit
Requirement
of Standard
(First Grade)
Testing
Results
Final
Result
Modulus Of Elasticity
Parallel To Sample Axis
Mpa >=5500 7150 Eligible
Modulus Of Elasticity
Quadrature to
Sample Axis
Mpa >=3500 4408 Eligible
Bending Strength
Parallel To Sample Axis
Mpa >=26 59.3 Eligible
Bending Strength
Quadrature to
Sample Axis
Mpa >=20 31.4 Eligible